Measured Runtime and Capacity Library

A measured record should show the model, output path, source, known test context, unknown conditions, and how the field result compares with the planning estimate.

Why rated Wh and delivered Wh differ

These are attributed third-party observations, not our hardware tests. Small continuous loads may deliver fewer Wh because an inverter remains active for longer. Efficiency also varies with load. Reported Wh and approximate watts × rounded hours need not agree; preserve the source's readings. Do not infer an inverter wattage from their difference.

Swipe table sideways
Delivered energy: Test load
ModelBelow 100 W100 W or moreDifference at higher load
EcoFlow DELTA 2
outdoorlife.com
~34 W · AC
690 Wh (67.4%)
~380 W · AC
900 Wh (87.9%)
+210 Wh
Anker SOLIX C1000
outdoorlife.com
~34 W · AC
650 Wh (61.6%)
~380 W · AC
950 Wh (90%)
+300 Wh
BLUETTI AC180
outdoorlife.com
~34 W · AC
620 Wh (53.8%)
~380 W · AC
980 Wh (85.1%)
+360 Wh
Goal Zero Yeti 700
outdoorlife.com
~34 W · AC
480 Wh (70.9%)
~380 W · AC
560 Wh (82.7%)
+80 Wh
Jackery Explorer 1000 Plus
outdoorlife.com
~34 W · AC
620 Wh (49%)
~380 W · AC
1,090 Wh (86.2%)
+470 Wh
VTOMAN FlashSpeed 1500
outdoorlife.com
~34 W · AC
770 Wh (49.7%)
~380 W · AC
1,219 Wh (78.7%)
+449 Wh

Same model, output and source series; temperature, battery endpoints and individual test dates remain unknown. These observations show a load association, not a controlled proof of its cause. Delivered Wh already include losses: do not subtract efficiency or overhead again.

Inverter draw: reported, with unresolved conditions

Outdoor Life attributes this AC inverter-and-port column to manufacturer replies. It is not an independently reproduced battery-side measurement. Load, interval, temperature and battery endpoints are unknown; these figures are not applied automatically in our calculator. Unavailable stays unknown. Recheck your exact setup before entering fixed overhead.

Swipe table sideways
Inverter draw: reported, with unresolved conditions
ModelReported drawObservation checked
EcoFlow DELTA 210 W · ACOutdoor Life · 2026-09-30
EcoFlow DELTA 316 W · ACOutdoor Life · 2026-09-30
BLUETTI AC18014 W · ACOutdoor Life · 2026-09-30
Goal Zero Yeti 7009 W · ACOutdoor Life · 2026-09-30
VTOMAN FlashSpeed 15004 W · ACOutdoor Life · 2026-09-30
Anker SOLIX C1000Unknown · ACOutdoor Life · 2026-09-30
Jackery Explorer 1000 PlusUnknown · ACOutdoor Life · 2026-09-30

Versioned measurement downloads

measurements-v1-0e3d1c15

No additional reuse license is granted. Check each original source and the site's terms; attribution does not replace permission./terms/

26 public measured recordsEach record has a third-party source URL and visible unknowns.
668 source-linked modelsMeasurements connect back to the model database.
Indexable evidence pageThe page is public because the first verified measured records are now attached.

Published test conditions

Coverage shows what third-party sources actually reported. Missing conditions stay unknown and are never filled with assumptions.

Swipe table sideways
Published test conditions
ConditionKnownUnknownCoverage
Average test load121446%
Ambient temperature0260%
Starting battery level0260%
Ending battery level0260%
Test date0260%

Measurement Records

Measured AC capacity tests show how much energy a station delivered in a third-party test, then compare that result with the site's default planning estimate.

Swipe table sideways
Measurement Records
ModelTestOutputMeasuredClaimedVs estimateSource
EcoFlow DELTA Pro 3Capacity test
Usable AC capacity test
Test load: Unknown
AC3,790 Wh
93%
Published conditions: 0/5
4,096 Wh+308 Wh (+9%)
3,482 Wh default planning estimate
OutdoorGearLab Best Power Stations of 2026
source date unknown; accessed 2026-09-04; test date unknown
EcoFlow DELTA ProCapacity test
Usable AC capacity test
Test load: Unknown
AC2,950 Wh
82%
Published conditions: 0/5
3,600 Wh-110 Wh (-4%)
3,060 Wh default planning estimate
OutdoorGearLab Best Power Stations of 2026
source date unknown; accessed 2026-09-04; test date unknown
Jackery Explorer 2000 v2Capacity test
Usable AC capacity test
Test load: Unknown
AC1,710 Wh
84%
Published conditions: 0/5
2,042 Wh-26 Wh (-1%)
1,736 Wh default planning estimate
OutdoorGearLab Best Power Stations of 2026
source date unknown; accessed 2026-09-04; test date unknown
EcoFlow RIVER 2 ProCapacity test
Usable AC capacity test
Test load: Unknown
AC620 Wh
81%
Published conditions: 0/5
768 Wh-33 Wh (-5%)
653 Wh default planning estimate
OutdoorGearLab Best Power Stations of 2026
source date unknown; accessed 2026-09-04; test date unknown
Goal Zero Yeti 700Capacity test
Usable AC capacity test
Test load: Unknown
AC560 Wh
83%
Published conditions: 0/5
677 Wh-16 Wh (-3%)
576 Wh default planning estimate
OutdoorGearLab Best Power Stations of 2026
source date unknown; accessed 2026-09-04; test date unknown
Jackery Explorer 300Capacity test
Usable AC capacity test
Test load: Unknown
AC260 Wh
89%
Published conditions: 0/5
293 Wh+10 Wh (+4%)
250 Wh default planning estimate
OutdoorGearLab Best Power Stations of 2026
source date unknown; accessed 2026-09-04; test date unknown
Anker SOLIX 521 PowerHouseCapacity test
Usable AC capacity test
Test load: Unknown
AC192 Wh
75%
Published conditions: 0/5
256 Wh-26 Wh (-12%)
218 Wh default planning estimate
OutdoorGearLab Best Power Stations of 2026
source date unknown; accessed 2026-09-04; test date unknown
EcoFlow DELTA 2Runtime test
Dehumidifier AC high-draw test (~380 W)
Test load: ~380 W
AC900 Wh
88%
Published conditions: 1/5
1,024 Wh+30 Wh (+3%)
870 Wh default planning estimate
Outdoor Life Best Portable Power Stations of 2026
2026-01-09; accessed 2026-09-04; test date unknown
Anker SOLIX C1000Runtime test
Dehumidifier AC high-draw test (~380 W)
Test load: ~380 W
AC950 Wh
90%
Published conditions: 1/5
1,056 Wh+52 Wh (+6%)
898 Wh default planning estimate
Outdoor Life Best Portable Power Stations of 2026
2026-01-09; accessed 2026-09-04; test date unknown
BLUETTI AC180Runtime test
Dehumidifier AC high-draw test (~380 W)
Test load: ~380 W
AC980 Wh
85%
Published conditions: 1/5
1,152 Wh+1 Wh (0%)
979 Wh default planning estimate
Outdoor Life Best Portable Power Stations of 2026
2026-01-09; accessed 2026-09-04; test date unknown
Goal Zero Yeti 700Runtime test
Dehumidifier AC high-draw test (~380 W)
Test load: ~380 W
AC560 Wh
83%
Published conditions: 1/5
677 Wh-16 Wh (-3%)
576 Wh default planning estimate
Outdoor Life Best Portable Power Stations of 2026
2026-01-09; accessed 2026-09-04; test date unknown
Jackery Explorer 1000 PlusRuntime test
Dehumidifier AC high-draw test (~380 W)
Test load: ~380 W
AC1,090 Wh
86%
Published conditions: 1/5
1,265 Wh+15 Wh (+1%)
1,075 Wh default planning estimate
Outdoor Life Best Portable Power Stations of 2026
2026-01-09; accessed 2026-09-04; test date unknown
VTOMAN FlashSpeed 1500Runtime test
Dehumidifier AC high-draw test (~380 W)
Test load: ~380 W
AC1,219 Wh
78%
Published conditions: 1/5
1,548 Wh-97 Wh (-7%)
1,316 Wh default planning estimate
Outdoor Life Best Portable Power Stations of 2026
2026-01-09; accessed 2026-09-04; test date unknown
EcoFlow DELTA 2Runtime test
Grow-light AC low-draw test (~34 W)
Test load: ~34 W
AC690 Wh
67%
Published conditions: 1/5
1,024 Wh-180 Wh (-21%)
870 Wh default planning estimate
Outdoor Life Best Portable Power Stations of 2026
2026-01-09; accessed 2026-09-04; test date unknown
Anker SOLIX C1000Runtime test
Grow-light AC low-draw test (~34 W)
Test load: ~34 W
AC650 Wh
62%
Published conditions: 1/5
1,056 Wh-248 Wh (-28%)
898 Wh default planning estimate
Outdoor Life Best Portable Power Stations of 2026
2026-01-09; accessed 2026-09-04; test date unknown
BLUETTI AC180Runtime test
Grow-light AC low-draw test (~34 W)
Test load: ~34 W
AC620 Wh
54%
Published conditions: 1/5
1,152 Wh-359 Wh (-37%)
979 Wh default planning estimate
Outdoor Life Best Portable Power Stations of 2026
2026-01-09; accessed 2026-09-04; test date unknown
Goal Zero Yeti 700Runtime test
Grow-light AC low-draw test (~34 W)
Test load: ~34 W
AC480 Wh
70%
Published conditions: 1/5
677 Wh-96 Wh (-17%)
576 Wh default planning estimate
Outdoor Life Best Portable Power Stations of 2026
2026-01-09; accessed 2026-09-04; test date unknown
Jackery Explorer 1000 PlusRuntime test
Grow-light AC low-draw test (~34 W)
Test load: ~34 W
AC620 Wh
49%
Published conditions: 1/5
1,265 Wh-455 Wh (-42%)
1,075 Wh default planning estimate
Outdoor Life Best Portable Power Stations of 2026
2026-01-09; accessed 2026-09-04; test date unknown
VTOMAN FlashSpeed 1500Runtime test
Grow-light AC low-draw test (~34 W)
Test load: ~34 W
AC770 Wh
50%
Published conditions: 1/5
1,548 Wh-546 Wh (-41%)
1,316 Wh default planning estimate
Outdoor Life Best Portable Power Stations of 2026
2026-01-09; accessed 2026-09-04; test date unknown
Jackery Explorer 5000 PlusCapacity test
Usable AC capacity test
Test load: Unknown
AC4,450 Wh
88%
Published conditions: 0/5
5,040 Wh+166 Wh (+4%)
4,284 Wh default planning estimate
HoboTech Jackery Explorer 5000 Plus review
2024-11-25; accessed 2026-09-04; test date unknown
EcoFlow DELTA Pro 3Capacity test
Usable AC capacity test
Test load: Unknown
AC3,810 Wh
93%
Published conditions: 0/5
4,096 Wh+328 Wh (+9%)
3,482 Wh default planning estimate
HoboTech EcoFlow Delta Pro 3 review
2024-06-26; accessed 2026-09-04; test date unknown
Jackery Explorer 3000 ProCapacity test
Usable AC capacity test
Test load: Unknown
AC2,540 Wh
84%
Published conditions: 0/5
3,024 Wh-30 Wh (-1%)
2,570 Wh default planning estimate
HoboTech Jackery 3000 Pro review
2023-03-28; accessed 2026-09-04; test date unknown
Jackery Explorer 3000 ProCapacity test
Usable DC capacity test
Test load: Unknown
DC2,618 Wh
87%
Published conditions: 0/5
3,024 Wh-104 Wh (-4%)
2,722 Wh default planning estimate
HoboTech Jackery 3000 Pro review
2023-03-28; accessed 2026-09-04; test date unknown
Growatt INFINITY 1500Capacity test
Usable AC capacity test
Test load: Unknown
AC1,230 Wh
81%
Published conditions: 0/5
1,512 Wh-55 Wh (-4%)
1,285 Wh default planning estimate
HoboTech Growatt Infinity 1500 review
2023-03-05; accessed 2026-09-04; test date unknown
EcoFlow RIVER 2 ProCapacity test
Usable AC capacity test
Test load: Unknown
AC640 Wh
83%
Published conditions: 0/5
768 Wh-13 Wh (-2%)
653 Wh default planning estimate
HoboTech EcoFlow River 2 Pro review
2023-04-06; accessed 2026-09-04; test date unknown
EcoFlow RIVER 2 ProCapacity test
Usable DC capacity test
Test load: Unknown
DC670 Wh
87%
Published conditions: 0/5
768 Wh-21 Wh (-3%)
691 Wh default planning estimate
HoboTech EcoFlow River 2 Pro review
2023-04-06; accessed 2026-09-04; test date unknown

Price per delivered Wh

Uses this test's delivered Wh, not rated capacity. Enter your own current price; no retailer prices or lifetime costs are implied.

Price per delivered Wh: —

Publication Criteria

These gates keep measured records separate from estimates.

Required

The model slug must match a source-linked station record.

Required

Capacity tests need measured Wh or usable percent; runtime tests need load watts.

Required

The output path must stay visible because AC, DC, and USB-C losses differ.

Required

Unknown third-party conditions stay unknown instead of being filled in.

Required

Computed estimates may only appear as comparison deltas, never as measured data.

How To Use Measured Data

Measured tests refine the estimate; they do not guarantee your setup.

Separate output paths

AC inverter, DC, and USB-C results should not be mixed because delivery losses change.

Show test context

Temperature, load profile, battery state, and stop conditions can change real results.

Keep estimates visible

The delta shows how the field result compares with default planning math.